Tubing Specifications
| Suggested Allowable Working Pressure Tables (psig) |
| Stainless Steel | | Tube Size O.D. | Tube Wall Thickness (inches) | | .028 | .035 | .049 | .065 | .083 | .095 | .109 | .120 | | 1/8" | 8500 | 10900 | | | | | | | | 3/16" | 5500 | 7000 | 10250 | | | | | | | 1/4" | 4000 | 5100 | 7500 | 10200 | | | | | | 5/16" | | 4050 | 5900 | 8050 | | | | | | 3/8" | | 3300 | 4800 | 6550 | | | | | | 1/2" | | 2500 | 3500 | 4700 | 6250 | | | | | 5/8" | | | 2900 | 4000 | 5200 | 6050 | | | | 3/4" | | | 2400 | 3300 | 4250 | 4950 | 5800 | | | 7/8" | | | 2050 | 2800 | 3600 | 4200 | 4850 | | | 1" | | | | 2400 | 3150 | 3650 | 4200 | 4700 | 75,000 PSI Tensile | Note: For welded and drawn tubing, a derating factor must be utilized. For double welded tube, multiply the above pressure rating by .85; and for single welded tube by .80 (ANSI B 31, Table A-1B). |
| Carbon Steel | | Tube Size O.D. | Tube Wall Thickness (inches) | | .028 | .035 | .049 | .065 | .083 | .095 | .109 | .120 | | 1/8" | 8100 | 10200 | | | | | | | | 3/16" | 5150 | 6650 | 9700 | | | | | | | 1/4" | 3750 | 4850 | 7100 | 10000 | | | | | | 5/16" | | 3750 | 5500 | 7600 | | | | | | 3/8" | | 3100 | 4500 | 6200 | | | | | | 1/2" | | 2300 | 3250 | 4500 | 5950 | | | | | 5/8" | | | 2600 | 3500 | 4600 | 5350 | | | | 3/4" | | | 2150 | 2900 | 3750 | 4350 | 5100 | | | 7/8" | | | 1800 | 2450 | 3200 | 3700 | 4300 | | | 1" | | | | 2100 | 2750 | 3200 | 3700 | 4100 | 47,000 PSI Tensile
| Copper | | Tube Size O.D. | Tube Wall Thickness (inches) | | .028 | .035 | .049 | .065 | .083 | .095 | .109 | .120 | | 1/8" | 2750 | 3700 | | | | | | | | 3/16" | 1700 | 2300 | 3500 | | | | | | | 1/4" | 1300 | 1650 | 2550 | 3550 | | | | | | 5/16" | | 1300 | 1950 | 2750 | | | | | | 3/8" | | 1050 | 1600 | 2250 | | | | | | 1/2" | | 800 | 1150 | 1600 | 2100 | | | | | 5/8" | | | 900 | 1250 | 1650 | 1950 | | | | 3/4" | | | 750 | 1000 | 1350 | 1550 | 1850 | | | 7/8" | | | 600 | 850 | 1100 | 1300 | 1550 | | | 1" | | | 550 | 750 | 950 | 1150 | 1350 | 1500 | 30,000 PSI Tensile
| Values in reverse text are not recommended for Gas Service |
|
|
|